A comparison of non-magnetic and magnetic beads for measuring IgG antibodies against Plasmodium vivax antigens in a multiplexed bead-based assay using Luminex technology (Bio-Plex 200 or MAGPIX)
dc.contributor.author | Mazhari, Ramin | en |
dc.contributor.author | Brewster, Jessica | en |
dc.contributor.author | Fong, Rich | en |
dc.contributor.author | Bourke, Caitlin | en |
dc.contributor.author | Liu, Zoe S.J. | en |
dc.contributor.author | Takashima, Eizo | en |
dc.contributor.author | Tsuboi, Takafumi | en |
dc.contributor.author | Tham, Wai Hong | en |
dc.contributor.author | Harbers, Matthias | en |
dc.contributor.author | Chitnis, Chetan | en |
dc.contributor.author | Healer, Julie | en |
dc.contributor.author | Ome-Kaius, Maria | en |
dc.contributor.author | Sattabongkot, Jetsumon | en |
dc.contributor.author | Kazura, James | en |
dc.contributor.author | Robinson, Leanne J. | en |
dc.contributor.author | King, Christopher | en |
dc.contributor.author | Mueller, Ivo | en |
dc.contributor.author | Longley, Rhea J. | en |
dc.date.accessioned | 2025-06-12T03:34:53Z | |
dc.date.available | 2025-06-12T03:34:53Z | |
dc.date.issued | 2020-12-04 | en |
dc.description.abstract | Multiplexed bead-based assays that use Luminex® xMAP® technology have become popular for measuring antibodies against proteins of interest in many fields, including malaria and more recently SARS-CoV-2/COVID-19. There are currently two formats that are widely used: non-magnetic beads or magnetic beads. Data are lacking regarding the comparability of results obtained using these two types of beads, and for assays run on different instruments. Whilst non-magnetic beads can only be run on flow-based instruments (such as the Luminex® 100/200™ or Bio-Plex® 200), magnetic beads can be run on both these and the newer MAGPIX® instruments. In this study we utilized a panel of purified recombinant Plasmodium vivax proteins and samples from malaria-endemic areas to measure P. vivax-specific IgG responses using different combinations of beads and instruments. We directly compared: i) non-magnetic versus magnetic beads run on a Bio-Plex® 200, ii) magnetic beads run on the Bio-Plex® 200 versus MAGPIX® and iii) non-magnetic beads run on a Bio-Plex® 200 versus magnetic beads run on the MAGPIX®. We also performed an external comparison of our optimized assay. We observed that IgG antibody responses, measured against our panel of P. vivax proteins, were moderately-strongly correlated in all three of our comparisons (pearson r>0.5 for 18/19 proteins), however higher amounts of protein were required for coupling to magnetic beads. Our external comparison indicated that results generated in different laboratories using the same coupled beads are also highly comparable (pearson r>0.7), particularly if a reference standard curve is used. | en |
dc.description.sponsorship | This work was supported by the National Health and Medical Research Council Australia (https://www.nhmrc.gov.au/) (#1092789, #1134989 and #1043345 to IM and #1143187 to W-HT), the National Institute of Allergy and Infectious Diseases (https://www.niaid.nih.gov/ grants-contracts/opportunities) (NIH grant 5R01 AI 104822 to JS) and the Global Health Innovative Technology Fund (https://www.ghitfund.org/) (T2015-142 to IM). Additional funding directly supporting field studies was from the TransEPI consortium (supported by the Bill and Melinda Gates Foundation, https://www.gatesfoundation. org/). RJL is currently supported by an NHMRC Early Career Investigator Fellowship (1173210). W. H.T. is a Howard Hughes Medical Institute-Wellcome Trust International Research Scholar (https://www.hhmi.org/programs/biomedicalresearch/international-programs, 208693/Z/17/Z). We also acknowledge support from the National Research Council of Thailand. This work was made possible through Victorian State Government Operational Infrastructure Support and Australian Government NHMRC IRIISS. These funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript. Additional support for this study was provided by CellFree Sciences in the form of salary for MH. The specific roles of these authors are articulated in the \u2018author contributions\u2019 section. | en |
dc.description.status | Peer-reviewed | en |
dc.format.extent | 14 | en |
dc.identifier.other | Scopus:85097310947 | en |
dc.identifier.other | PubMed:33275613 | en |
dc.identifier.uri | http://www.scopus.com/inward/record.url?scp=85097310947&partnerID=8YFLogxK | en |
dc.identifier.uri | https://hdl.handle.net/1885/733760103 | |
dc.language.iso | en | en |
dc.rights | Publisher Copyright: © 2020 Mazhari et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. | en |
dc.source | PLoS ONE | en |
dc.title | A comparison of non-magnetic and magnetic beads for measuring IgG antibodies against Plasmodium vivax antigens in a multiplexed bead-based assay using Luminex technology (Bio-Plex 200 or MAGPIX) | en |
dc.type | Journal article | en |
local.contributor.affiliation | Mazhari, Ramin; Walter and Eliza Hall Institute of Medical Research | en |
local.contributor.affiliation | Brewster, Jessica; Walter and Eliza Hall Institute of Medical Research | en |
local.contributor.affiliation | Fong, Rich; Case Western Reserve University | en |
local.contributor.affiliation | Bourke, Caitlin; Walter and Eliza Hall Institute of Medical Research | en |
local.contributor.affiliation | Liu, Zoe S.J.; Walter and Eliza Hall Institute of Medical Research | en |
local.contributor.affiliation | Takashima, Eizo; Ehime University | en |
local.contributor.affiliation | Tsuboi, Takafumi; Ehime University | en |
local.contributor.affiliation | Tham, Wai Hong; Walter and Eliza Hall Institute of Medical Research | en |
local.contributor.affiliation | Harbers, Matthias; CellFree Sciences Co., Ltd. | en |
local.contributor.affiliation | Chitnis, Chetan; Institut Pasteur Paris | en |
local.contributor.affiliation | Healer, Julie; Walter and Eliza Hall Institute of Medical Research | en |
local.contributor.affiliation | Ome-Kaius, Maria; Walter and Eliza Hall Institute of Medical Research | en |
local.contributor.affiliation | Sattabongkot, Jetsumon; Mahidol University | en |
local.contributor.affiliation | Kazura, James; Case Western Reserve University | en |
local.contributor.affiliation | Robinson, Leanne J.; Walter and Eliza Hall Institute of Medical Research | en |
local.contributor.affiliation | King, Christopher; Case Western Reserve University | en |
local.contributor.affiliation | Mueller, Ivo; Walter and Eliza Hall Institute of Medical Research | en |
local.contributor.affiliation | Longley, Rhea J.; Walter and Eliza Hall Institute of Medical Research | en |
local.identifier.citationvolume | 15 | en |
local.identifier.doi | 10.1371/journal.pone.0238010 | en |
local.identifier.pure | fc55ff51-bebc-41bb-bb07-df6318997be0 | en |
local.type.status | Published | en |